Note: Water, isopropyl alcohol (Isopropyl, rubbing alcohol), and plate cleaners containing isopropyl alcohol are not recommended.Ĭleaning method: Lint free cloth/Spray airĪdditional (residue persists): Anhydrous alcohol Cleaning solutions other than those recommended can contain chemicals that cause visible or hidden damage to the plate and could result in immediate or future image artifacts. Do not pour the cleaning solution directly onto the plate. When using a cleaning solution, apply the solution to a clean, soft, lint-free cloth. Comfortable for the patient, 100 active area DIGORA® Optime wireless and exible imaging plates together with soft hygiene bags are very comfortable for the patient. Use a lint-free cloth dampened with ethanol anhydride to remove stains that do not come off easily. Dynamic and tough imaging plates DIGORA® Optime imaging plates with high wear resistance serve you time after time, making the use of the system cost-eective. Use lint-free cotton to wipe the imaging plates. This is done to prevent damage and keep dust and contaminants off of the phosphor plate.Ĭleaning Method : Place the plate with the black (non-phosphor) side down on a clean, dry, non-abrasive surface, such as a lint free cloth. Storage Environment: Imaging plates must be stored in their protective barriers. Handle flexible phosphor plates with care. Certain chemical agents, such as non-approved plate cleaners, hand lotions, topical medications, food, etc., may also damage the plates.

soredex digora optime imaging plates #2

This may occur from abrasion of the protective overcoat or inadvertent physical damage to the surface or edge. Plate wear can result in artifacts on radiographs. Under normal use conditions, phosphor plates will eventually show wear. For best results, wear clean, soft, lint-free fabric gloves.

#Soredex digora optime imaging plates #2 manual

Avoid contact with the plate's blue (phosphor) side. DIGORA Optime DXR-50 001 Digital intraoral imaging plate system User’s Manual This unit is marked according to the Medical Device Directive 93/42/EEC (if the unit contains the CE mark) Document number 204253 rev 2 (0908) Original approved English language version Manufactured by SOREDEX P. Handling: Hold plates by the edges and by the black side.

soredex digora optime imaging plates #2

#Soredex digora optime imaging plates #2 how to

Digital Solutions- Learn how to clean the Optime plates








Soredex digora optime imaging plates #2